RADbus¶
RADaero devices communicate over a CAN FD-based network, using a custom message protocol designed for reliability, performance and security. Messages are broadcast across a shared bus, so multiple devices can exchange data simultaneously. Every message has an identifier that defines both its purpose and its priority, so time-critical data goes first.
Wiring¶
- One RADaero device: leave the RADbus high and low wires disconnected.
- Multiple devices: connect all RADbus high wires together, and all RADbus low wires together.
| Device | RADbus high | RADbus low |
|---|---|---|
| AwesomeEFIS | Pin 2, Green | Pin 7, Green / Black |
| AwesomeADSB | Pin 5, Green | Pin 6, Green / Black |
Termination¶
Every device has a CAN bus termination resistor that can be enabled or disabled individually. Proper RADbus termination is essential for communication. Exactly 2 devices on the RADbus need termination enabled. Disable termination on all other devices.
| Device | How to enable termination |
|---|---|
| AwesomeEFIS | Jumper pin 5 to pin 10. The included harness has the jumper installed. |
| Extra Display | Jumper pin 5 to pin 10. A jumper wire ships in the packaging. |
| AwesomeADSB | Set CAN Termination to On on its configuration page. |
The recommended configuration is to enable termination on the EFIS and on the device furthest from it by wire length. Contact support@RAD.aero for guidance on your particular installation.